Modules Programming Guide - 17
DGP2-ZX1 V2.0
1-zone Expansion Module
Input speed = Base Time X Time Value (Default: 600ms)
U = Default setting
Section [001] General Options
Option OFF ON
[1] Tamper Recognition U
Disabled
NEnabled
[2] to [8] Future Use N N/A N N/A
Sections Base Time Description Default
[002] __/__/__ (000 = 15 ms)
For the Base Time, using Level Programming, press
the and buttons to select a value from
000 to 002 and then press [
ENTER].
n/a
__/__/__ (001 = 1second)
n/a
__/__/__ (002 = 1 minute)
Section Time Value
[003] ___/___/___ (001 to 255)