Digiplex Modules Programming Guide - 13
Motion Detector Modules
U = Default setting
SECTION [001] : General Options
Option OFF ON
[1]
Single/Dual Edge Processing N Dual Edge
U Single Edge
[2] Alarm Indication
(red LED illuminates for 5 secs.)
N Disabled
U Enabled
[3] Movement Signal Indication
(red LED will flash)
N Disabled
U Enabled
[4] Non-movement Signal Indication
(green LED will flash)
N Disabled
U Enabled
[5] Tamper Recognition
U Disabled
N Enabled
[6] Future Use N N/A N N/A
[7] Future Use N N/A N N/A
[8] Future Use N N/A N N/A
Section #
[002]
Digital Shield Setting
___/___/___ (000 to 003 sensitivity; Default: 002)
000 = Very Low Shield, 001 = Low Shield, 002 = Normal Shield, 003 = High Shield
DGP2-60 V2.0 DGP2-70 V2.0