26 - Digiplex Modules Programming Guide
Access Control Module
U = Default setting
* = V2.0 or higher
** = V1.1 or higher
*** = V1.02 or higher
Enable option [8] in section [004] if the DGP2-ACM1P’s power supply is not being used. This disables AC and battery power supervision
and prevents a trouble from being generated.
SECTION [001] : Partition Assignment SECTION [002] : General Options 1
Option OFF ON Option OFF ON
[1] Partition 1 N Disabled
U Enabled
[1]
Tamper Input
U Disabled
N Enabled
[2] Partition 2
U Disabled
N Enabled [2]
Battery Charging Current
U 350mA
N 700mA
[3] Partition 3
U Disabled
N Enabled [3] Reader’s red LED to follow partition’s
status
N Disabled
U Enabled
[4] Partition 4
U Disabled
N Enabled [4] Reader’s beeping to follow partition’s
status when option [3] is ON
N Disabled
U Enabled
[5] Partition 5
(DGP-NE96 only)
U Disabled
N Enabled [5] Card activates door unlocked
schedule
U Disabled
N Enabled
[6] Partition 6
(DGP-NE96 only)
U Disabled
N Enabled [6] Door will relock
U Imme-
diately
N When
closed
[7] Partition 7
(DGP-NE96 only)
U Disabled
N Enabled [7] Reader’s green LED for Access
Granted
N Disabled
U Enabled
[8]
Partition 8
(DGP-NE96 only)
U Disabled
N Enabled [8]
Unlock on Request for Exit (REX)
U Disabled
N Enabled
SECTION [003] : General Options 2 SECTION [004] : PGM Options
Option OFF ON Option OFF ON
[1] Door Left Open Alarm
U Disabled
N Enabled [1] PGM Deactivation After
U
Deactiva-
tion Event
N
PGM Timer
[2] Door Left Open Pre-alarm N Disabled
U Enabled
[2] PGM Normal State
U N.O.
N N.C.
[3] Door Left Open Alarm N Silent
U Audible
[3] PGM Base Time
U 1 second
N 1 minute
[4] Door Left Open Alarm follows
U Alarm
Restore
N Beep
Timer
[4] Future Use N N/A N N/A
[5] Door Forced Open Alarm
U Disabled
N Enabled [5] PIN entry on PosiPIN
(Note 1 on page 28)
U Disabled
N Enabled
[6] Door Forced Alarm N Silent
U Audible
[6] Reader Locate Feedback*
U Visual
N Visual &
audible
[7] Door Forced Alarm follows
U Alarm
Restore
N Beep
Timer
[7] Unlock Door on Fire Alarm*
U Disabled
N Enabled
[8] Reader Access Feedback
U Visual
N Visual &
audible
[8] AC and Battery Supervision**
U Enabled
N Disabled
Section Data Description Default
[005]
__/__/__ (000 to 255 x 1 minute; 000 = Instant) AC failure report delay 000
[006]
__/__/__ (001 to 255 seconds) Door Unlocked Period 005
[007]
__/__/__ (001 to 255 seconds added to section [006]) Door Unlocked Period extension 015
[008]
__/__/__ (001 to 255 seconds) Door Left Open Interval 060