32 - Digiplex Modules Programming Guide
LCD Keypad Module (DGP2-641/BL/R/RB) 48-Zone LED Keypad Module (DGP2-648)
LCD Keypad (DGP2-641/BL/R/RB)
Memory Key Connector
To Digiplex
control panel
(DGP-848 or
DGP-NE96)
Please Note: The keypad’s
anti-tamper switch will
communicate its status to the
control panel via the combus.
* The keypad’s zone
follows the control
panel’s EOL definition.
The zone speed is set at
600mS and cannot be
programmed.
Door Contact
Combus
To Digiplex
control panel
(DGP-848 or
DGP-NE96)
LED Keypad (DGP2-648)
Please Note: The keypad’s
anti-tamper switch will
communicate its status to the
control panel via the combus.
* The keypad’s zone
follows the control
panel’s EOL definition.
The zone speed is set at
600mS and cannot be
programmed.
Door Contact
Combus
DGP2-641R/RB Access Control Connections
DGP2-641R DGP2-641R
Fused external power
supply (recommended)
Door Lock
IN4007
Diode
DGP2-641R
Paradoor (460)
Request to Exit device.
Must be connected to
Z2
terminal.
If a door contact is not being used, install a
jumper or a 1k
9
resistor across the BLK and Z1
terminals depending on the control panel’s EOL
definition.
If the REX (Request for Exit) device is not being
used, place a jumper across the
BLK and Z2
terminals.
Door Contact
Must be connected
to
Z1 terminal.
* Follows control panel’s EOL definition.
No EOL
required for
Z2.