Seitenansicht 47
44 Reference & Installation Manual
15 WinLoad Software
The Winload software is not verified by UL.
15.1 Answering Machine Override
SECTION [441]
When using WinLoad to communicate remotely with an installation site
that uses an answering machine or service, the Answering Machine
Override must be programmed. Using WinLoad, call the installation
site and on the second ring press the
[ENTER]
key on the keyboard to
hang up or hang up manually. After hanging up, WinLoad will
immediately call the installation site back or call the site back manually.
The value (00 to 15 X 4 seconds) programmed in section
[441]
represents the delay period the control panel will wait between the first
and second call. If the installation site is called back within the
programmed delay period, the control panel will override the answering
machine or service by picking-up the line on the first ring. To disable
this option program 00 in section
[441]
. Also, see section 15.2.
Example: A security installation is using an answering machine set
to answer after three rings and section [441] has been
programmed with 10 (10 x 4 = 40 seconds). When you call the
installation site with WinLoad the first time, wait two rings and press
[
ENTER] on the keyboard. WinLoad will immediately call the
installation site back. If the second call is made within 40 seconds,
the control panel will pick-up the line on the first ring. If it takes
more than 40 seconds, the control panel will not answer on the first
ring and the answering machine will answer after three rings.
15.2 Ring Counter
SECTION [442]
The value (01 to 15, 00 = disabled) programmed in section [442]
represents the number of rings the control panel will wait before
picking-up the line. If the line is not answered after the number of
programmed rings, the control panel will answer the call. The control
panel resets the Ring Counter every 10 seconds. Therefore, if there
is more than 10 seconds between each ring, the control panel will
reset the counter on the next call. Also, see section 15.1.
15.3 Panel Identifier
SECTION [555]
This four-digit code identifies the control panel to WinLoad before
initiating upload or download. The control panel will verify if the
panel identifier in WinLoad is the same. If the codes do not match,
the control panel will not establish communication. Therefore,
program the same Panel Identifier into both the Digiplex Control
Panel and WinLoad. To program the Panel Identifier, key in the
desired 4-digit hexadecimal number into section [555].
15.4 PC Password
SECTION [556]
This four-digit password identifies the computer running the WinLoad
software to the panel before beginning the download process.
Program the same PC Password into both the Digiplex control panel
and WinLoad. If the passwords do not match, WinLoad will not
establish communication. To program the PC Password, enter the
desired four-digit hexadecimal number into section [556].
15.5 PC Telephone Number
SECTION [560]
The control panel will dial this number when trying to initiate
communication with a computer using WinLoad. You can enter any
digit from 0 to 9 and any special keys or functions (see Table 10,
Special Telephone Number Keys, on page 27) up to a maximum of
32 digits into section [560].
For North American installations using either SIA or
Contact ID reporting formats (see section 8.5 on page
27), enter *70 and then either P (4-second pause) or W
(wait for second dial tone) before the phone number to
disable call-waiting.
15.6 Call WinLoad
Dial the PC Telephone Number programmed in section [560] in
order to communicate with WinLoad. The control panel and
WinLoad will verify that the Panel Identifier and the PC Password
match before establishing communication.
For LCD keypads: press and hold the [0] key, enter the [
INSTALLER
CODE] and then press [FORCE].
For Grafica keypads: press and hold the [0] key, enter the
[INSTALLER CODE], press the center action key (Options), highlight
Call Winload and then press the left action key (Select).
15.7 Answer WinLoad
To perform on-site upload/downloading, connect your computer
directly to the control panel using an ADP-1 line adapter. In
WinLoad set Dialing Condition to Blind Dial. Program the panel
telephone number in WinLoad and follow the ADP-1 Adapter‘s
instructions. When the computer has dialed...
For LCD keypads: press and hold the [0] key, enter the [
INSTALLER
CODE] and press [ARM] to manually answer WinLoad from the
panel. Press [DISARM] to hang up.
For Grafica keypads: press and hold the [0] key, enter the
[INSTALLER CODE], press the center action key (Options), highlight
Answer Winload and then press the left action key (Select). To
hang up, highlight Cancel Communication and then press the left
action key (Select).
15.8 Event Buffer Transmission
SECTION [522]: OPTION [2]
If the Event Buffer contains 974 events since the last upload, the
control panel will make two attempts to establish communication
with a computer using WinLoad by calling the PC Telephone
Number programmed in section [560]. WinLoad must be in Wait To
Dial mode. When the system establishes communication, it will
upload the contents of the Event Buffer to WinLoad. If
communication is interrupted before completing transmission or if
after two attempts, communication is not established, the system
will wait until the Event Buffer attains another 974 events before
attempting to re-communicate with the monitoring station. When
the Event Buffer is full, each subsequent new event will erase the
oldest event in the buffer. The Event Buffer can hold 1024 Events.