Seitenansicht 17
14 User Manual
5.9.1 Bypass Recall
The Bypass Recall feature enables you to bypass the same zones
that were bypassed previously at the touch of a key.
How do I bypass a zone?
1) Enter your [
ACCESS CODE]. Your keypad will emit a Confirmation
Beep and the A
CCESS action light will flash.
2) Press the [
BYP] key. The PRG action light will illuminate and the
B
YP action light will flash.
3) Enter the two-digit number(s) of the zone(s) you want to bypass
and the corresponding number(s) will illuminate. If a zone’s
number is illuminated and you reenter its number, the zone will
unbypass and the number will extinguish.
If a zone’s number does not illuminate and your keypad emits a
Rejection Beep, the zone may not have the Bypass feature accessible.
4) Press the [
ENTER] key to save and exit. The BYP action light will
remain illuminated to indicate that zones are bypassed.
How do I activate Bypass Recall?
1) Enter your [
ACCESS CODE]. Your keypad will emit Confirmation
Beep and the A
CCESS action light will flash.
2) Press the [
BYP] key. Your keypad will emit a Confirmation Beep and
the P
RG action light will illuminate. The BYP action light will also flash.
3) Press the [
MEM] key. All zones (numerical lights) bypassed during the
last time the system was armed will illuminate and will be bypassed.
4) If you wish, reenter the zone’s number to change a bypassed
zone to an unbypassed zone and vice versa.
5) Press the [
ENTER] key to exit.
DGP2648_EU08.fm Page 14 Friday, September 29, 2006 2:43 PM