Digiplex -EVO- - 50 - Programming Guide
Download Memory Key to Control Panel.
1) Insert the Memory Key (PMC-5) onto the control panel’s connector labelled “MEM KEY”.
2) To download the contents of the Memory Key except zone numbering and sections [0501] to [0532], enter installer programming mode
and then enter section [4010]. (Depending on the memory key, the labels may or may not be included.)
To download the contents of the Memory Key including zone numbering and sections [0501] to [0532], enter installer programming
mode and then enter section [4011].(Depending on the memory key, the labels may or may not be included.)
3) When the keypad emits a confirmation beep, remove the Memory Key.
Copy Control Panel to Memory Key
1) Insert Memory Key (PMC-5) onto the control panel’s connector labelled “MEM KEY”. Ensure the write protect jumper on the memory
key is on.
2) To copy the contents to the Memory Key except zone numbering and sections [0501] to [0532], enter installer programming mode,
then enter section [4020]. (Depending on the memory key, the labels may or may not be included.)
To copy the contents to the Memory Key including zone numbering and sections [0501] to [0532], enter section [4021].
(Depending on the memory key, the labels may or may not be included.)
3) After the confirmation beep, remove the Memory Key. Remove the Memory Key’s jumper if you do not wish to accidentally overwrite
its contents.
When using the PMC-3 Memory Key, sections [4010], [4011], [4020] and [4021] will NOT include the labels. Use sections [4012] and [4022]
to transfer labels only using a PMC-4 or PMC-5.
Automatic Report Code Programming
When using Contact ID or SIA Reporting formats (section [3070] on page 36), default report codes can be programmed automatically. After automatic
defaults are set, they can be changed and the remaining report codes can be set manually.
Software Reset
Performing a software reset will set certain parameters to default values. To do so:
1) Enter Programming Mode (see Entering Programming Mode on page 3).
2) Enter Section [4049] to unlock software reset.
3) Enter the 4-digit [
SECTION] corresponding to the software reset you wish to perform.
4) If you want to reset more than one section, enter section [4049] to unlock the software reset again.
[4022] Copy the control panel user label to the Memory Key. (See warning on page 50)
[4023] Copy the control panel installer default to the Memory key.
Section Description
[4030]
ALL REPORT CODES RESET TO 00
Resets all the report codes from sections [0201] to [0296], [0701] to [0832],
[2001] to [2199] and [3900] to [3999] to 00.
Sections [4031] to [4037] reset all the report codes in the following sections to
the default values from the “Automatic Report Codes List” on page 47.
[4031]
ALL REPORT CODES RESET TO FF [0201] to [0296], [0701] to [0832], [2001] to [2199] & [3900] to [3999]
[4032]
ZONE ALARM/ALARM RESTORE AND ZONE TAMPER/TAMPER
R
ESTORE REPORT CODES
[0201] to [0296]
[4033]
USER/KEYSWITCH ARMING & DISARMING REPORT CODES [0701] to [0832], and [2001] to [2199]
[4034]
SPECIAL CODES [3900] to [3909]
[4035] S
PECIAL ARMING/DISARMING REPORT CODES [3910] to [3929]
[4036] S
PECIAL ALARM REPORT CODES [3930] to [3939]
[4037] T
ROUBLE & TROUBLE RESTORE REPORT CODES [3940] to [3999]
Can copy and
download content
Cannot overwrite